low profile drop ceiling exhaust fans

- 6" - 435 cubic feet of HEAT, GONE in a minute - cools 500 sq. ft. of floor space. Cooling Server Rooms, cools up to 9 servers
- Cools servers, Bitcoin Mining Rigs, 3D Printers
- Horizontal intake removes the HOTTEST AIR @ the ceiling
- Automatic - adjustable thermostat
- 110 volts - 1 amp - 115 watts
- Fits standard 2 x 2 ceiling grid / EASY Install
- Fully assembled = 10 year guarantee
- 15 - 20 year service life
- Needs 16" of Clearance from Ceiling Grid
- Galvanized Steel/ welded, Built to last.
- free exhaust or ducted,
- 2 cool air intakes included
-
2 day shipping
- Call Dane @ 770.480.9913
- more exhaust systems, stmfab.net, top of page, exhaust systems drop down
-
DPE 480,low profile,. Less shipping lowers cost
Longer power cord to plug into a wall outlet. Easier to install than hard wiring to fan
stranded 16-2 with ground
$1.00/FT includes shipping. Specials $1 each
Duties !/$
speed adjuster 49 @ $1 each
Call Dane @ 770.480.9913
- 12" - 1060 Cubic Feet of HEAT,odor, fumes, smoke Gone in a Minute -Cools to 1400 Sq. Ft. of floor space. Server Room Cooling, Cools up to 21 servers
- Cools servers,Bitcoim Mining Rigs, 3D Printers FAST
- Horizontal Exhaust
- Horizontal Intake Removes only the HOTTEST Air @ the Ceiling
- Automatic - adjustable thermostat
- 110 volts - 3 amps - 300 watts
- Fits standard 2 x 2 ceiling grid / EASY install
-
Fully assemble - 10 year guarantee
- 15 - 20 year service life
- Galvanized Steel/Welded-Built to Last
- Needs 16" of clearance from the ceiling grid
- Free exhaust or ducted to return air plenum, "Y" into existing exhaust pipe
- 2 cool air intakes included
- 2 day shipping
- Call 770.480.9913
- "R" price reduced, offsets shipping costs
Wall Switched applications, Bathrooms, Air Circulation, Heat Removal, Etc
exhausts to 900 sq.ft.
2 x 2 ceiling grid, free exhaust or ducted.
Customer provided switch - On/Off Switch, Timer, etc
10 year warranty 15 -20 year service life
2 day shipping
"R" price reduced, offsets shipping costs
Thermostat, Motion Switch
435 CFM Exhaust, 110 volt, 1 amp, 115 Watts
Fully Assembled, 10 year Warranty
2 cool air intakes included
Call Dane @ 770.480.9913
Cooling Server Rooms, quietly for occupied rooms
Server Room, Data Center & equipment rooms Cooling. Exhausts 435 cubic feet/minute of hottest air. Thermostat controlled. easy install. 110 volt,10 year warranty cools 500 sq. ft.
Quiet version of SC-6H - 63 down to 46 decibels. Make a large difference to employee occupied spaces. Sch-6h removes hot air @ ceiling, pulls cool air in from the floor level of next room(cool air intakes included) Faster & less expensive than air conditioning. 25 feet of flex duct (snaked) cancels sound waves.
Horizontal exhaust. 18" ceiling clearance
other exhaust systems, top of page drop down, STMFAB.NET
Check the DCE systems, quiet for a open area above the ceiling
Call Dane @ 770.480.9913
745 CFM Exhaust, Air circulation, Exhaust Bathroom, General Rooms
exhausts 900 sq. ft.
2 X 2 Ceiling Grid, free exhaust or ducted, wall switched
Fully Assembled, 10 Year Warranty
15 - 20 year service life
110 Volt, 1.7 Amps, 200 Watts
customer provided - Timer,On/Off,Thermostat, Motion sensor, any 110 volt switch
2 cool air intakes included
2 day shipping
Call Dane @ 770.480.9913
"R" price reduced, offsets shipping costs
8" - 745 c.f.m. exhaust -68 down to 58 decibels - 2 panel system, 1 side intake & 1 acoustic ceiling tile with fan motor & adjustable thermostat. 2 x 2 grid, 110 volt, 1.7 amp, 115 watts - horizontal exhaust. 6' of silver flex duct, duct tape & 2 cool air intakes included. Occupied server room use recommended for reduced sound level.
10 year warranty. 15 - 20 year service life
Server Room Cooling, cools up to 15 servers
Cools 900 sq. ft.
Cools Servers, Bitcoin mining rigs, 3D printers, Hot Rooms.
Other exhaust systems at STMFAB.NET top of page, Exhaust Systems
Call Dane @ 779.480.9913
Server Room Cooling (no modification lease) w/o xtra A C unit
Pulls Cool air from next room, pulling from a 75 degree room delivers about 73 degree air to your server room
Works with the 8" SC 8H exhaust for increased cost savings, sound insulated & reliable
Uses 2 ceiling tiles (2 x 2) one intake, one for motor & thermostat, in acoustic tile
8" duct reduced to 6" at intake & exhaust panel, pulls cooler air from center & lower portion of room & exhaust to floor of room to be cooled.
110 volt - 1.7 amp - 115 watts - thermostat - fully assembled - 10 year warranty
Easy install - No maintenance - No refrigerant or water leaks - No floor Space - No service calls
10% of the operating cost of an extra A.C. unit. Lower initial & installation costs.
more exhaust systems to Cool Server Rooms @ STMFAB.NET home page
top right of page
Questions? Dane @ 7704809913
Fine tune the Hot Air Axe.
Decrease sound level & Exhaust output.
Do not adjust to constant "on"
1 year warranty- mounted so it can be replaced in time.
Cools Server Rooms ( no modification leases) w/o extra A C unit
Pulls cold air from next room, exhausts the hottest air, above the ceiling.
Works as buddy system with SC 6 exhaust system, sound insulated, cost savings, reliable
Pulling from 75 degree room, you will get about 73 degree air to your server room.
Uses 2 ceiling tile spaces ( 2 x 2 ), 1 intake for cooler air, 1 houses motor & thermostat in acoustic ceiling tile.
6" fan reduced to 4" straight inlet & exhaust to "tunnel" to lower (cooler air) level of rooms & get cooler air to floor
110 volt - 1 amp - 115 watts - thermostat - fully assembled - cool air supplies 500 sq. ft.
2x2 drop ceiling - Easy install - No floor space required - no refrigerant or water leaks- easy , less expensive installation
10 year guarantee - No maintenance - No leaks - No service agreement
10 % of the operating cost of A.C. , Lower initial & installation costs.
More exhaust systems to Cool Server Rooms @ stmfab.net, top right of page
Questions ? Dane @ 7704809913
The Negative Pressure System is designed to exhaust air from up to a 450 square foot room,with a drop ceiling. Restricting air intake to a closed room, creates Negative Pressure.
2' x 2" ceiling grid, 14" clearance above the ceiling grid
* Exclusive side intake @ ceiling removes more of hottest air @ ceiling
* Exhausts 0-435 cubic feet of air, rotary dial speed adjuster with on/off switch is mounted on intake plate. UNFILTERED EXHAUST
*adjustable thermostat
* Intake plate drops 1" below the ceiling grid, creating a larger intake radius @ the ceiling.
* 6" fan motor to be ducted to outside air, per CDC.
* Commercial duty motor, 10 year warranty
* 15 - 20 year service life
* 2 air intake grills included, mount 3" above floor, in door.
* all our systems are Negative pressure, 6", 8", 10", 12"
* 2 day shipping
* 110 volt - 1 amp- 115 watt - weight 16# Questions? Dane @ 770.480.9913
Drop ceiling exhaust cools server rooms & data centers by pulling hot air out at ceiling, pulls cool air from next room thru cool air intakes (included). Pancake design, cheaper shipping. 3 1/2 " above ceiling grid, exhausts full 24" wide
Exhausts 480 cubic feet /minute,2 fan motors, dual ball bearing , metal frame, 50,000 hour life, low profile, 110 volts, fully assembled, 5 year warranty.
2 x 2 grid, easy installation, adjustable thermostat 50- 90 degrees , low profile for less shipping cost
Fast shipping
SC6H Quiet switched is a 1 panel exhaust, 435 CFM, 1 amp, 110 volt, utilizing 25' of silver flex duct.
1 acoustic panel motor panel. Client provides any 110 volt switch. Primarily used in an occupied area. Any 110 volt switch ( customer provided)
10 year warranty
service life of 15 - 20 years